Faults and their correction

Observe the documents of all the components used in addition to this product which are necessary for the work process.

Contact your retailer or ABICOR BINZEL in the event of questions or problems.

Fault

Cause

Correction

Extraction volume too low.

Filter saturated.

Replace the filter. Replacing the pre-filter and Replacing the main filter

Extraction hose blocked.

Clean extraction hose.

Extraction hose faulty.

Replace extraction hose. Replacing the extraction arm

Extraction hood valve closed.

Open the extraction hood valve further. Controlling the volume flow

Service LED illuminates continuously.

Filter saturated.

Replace the filter. Replacing the pre-filter and Replacing the main filter

Extraction does not start.

Power supply not OK.

Check the electrical connection.

Check cables for damage and have them replaced by a qualified electrician if necessary or contact the service team.

Electrical component faulty.

Protective motor switch faulty.

Check and have them replaced by a qualified electrician if necessary or contact the service team

Dust is escaping the system.

Filter saturated.

Replace the filter. Replacing the pre-filter and Replacing the main filter

Service door not closed.

Close the service door.