Faults and troubleshooting

Consult the documentation of all components used.

Contact your retailer or ABICOR BINZEL in the event of questions or problems.

Fault

Cause

Correction

Extraction volume too low.

Filter elements saturated.

Replace the filter cartridges. Replacing filter cartridges

Dust collection bin leaking.

Check the dust collection bin and fit it properly. Emptying the dust collecting container

Extraction hose blocked.

Clean extraction hose.

Extraction hose faulty.

Replace extraction hose. Attaching the extraction hose

Extraction system does not start up.

Power supply not OK.

Check and replace as needed, or contact customer service Replacing the carbon brushes.

Electrical component faulty.

The carbon brushes are defective.

Current clamp is not mounted correctly.

Mount the current clamp properly Mounting the Current Clamp.

Dust is escaping from the dust collection bin.

Dust collection bin leaking.

Check the dust collection bin and fit it properly. Emptying the dust collecting container

Dust collection bin full.

Empty the dust collection bin. Emptying the dust collecting container

Filter dedusting is not working.

Compressed air supply not OK.

Check the compressed air supply and replace if necessary.

Filter cartridges not inserted correctly.

Check filter cartridges for correct placement and insert correctly if necessary. Replacing filter cartridges

Rotary nozzles tilted or damaged.

Check the rotary nozzles and contact customer service if necessary.

End caps of the rotary nozzles loose or fallen off.

Check the top and bottom end caps of both rotary nozzles and contact customer service if necessary.

Service LED illuminates continuously.

Filter cartridges or filter membranes are defective/saturated.

Set the <On/Off> switch to <Off> to clean the filter membrane.

The filter membranes are cleaned twice.

Change filter cartridges. Replacing filter cartridges

The power LED illuminates after initialization but the motors fail to start.

Control board defective.

Check and replace the control board as needed, or contact customer service.

Power relay defective

Check and replace the power relay as needed, or contact customer service.