Maintenance and cleaning intervals

The given intervals are for guidance and refer to one-shift operation. We recommend documenting the checks. At least the test date, the defects found and the name of the tester should be documented.

Table: Maintenance and Cleaning Intervals

Interval

Job

After 2 operating hours or when the service LED illuminates

Run the cleaning process Operation

Change filter cartridges. Replacing filter cartridges

Daily

Empty the dust collection bin. Emptying the dust collecting container

Weekly

Check the operating hours meter.

Monthly

Check the device for visible damage.

After approx. 800 operating hours

Carbon brushes must be replaced only by a qualified electrician. Replacing the carbon brushes

After two carbon brush replacements

Have motors replaced by a qualified electrician. Replacing the motors