Fault | Cause | Correction |
---|---|---|
Extraction volume too low. | Filter elements saturated. | Replace the filter cartridges. Replacing filter cartridges |
Dust collection bin leaking. | Check the dust collection bin and fit it properly. Emptying the dust collecting container | |
Extraction hose blocked. | Clean extraction hose. | |
Extraction hose faulty. | Replace extraction hose. Attaching the extraction hose | |
Extraction system does not start up. | Power supply not OK. | Check and replace as needed, or contact customer service Replacing the carbon brushes. |
Electrical component faulty. | ||
The carbon brushes are defective. | ||
Current clamp is not mounted correctly. | Mount the current clamp properly Mounting the Current Clamp. | |
Dust is escaping from the dust collection bin. | Dust collection bin leaking. | Check the dust collection bin and fit it properly. Emptying the dust collecting container |
Dust collection bin full. | Empty the dust collection bin. Emptying the dust collecting container | |
Filter dedusting is not working. | Compressed air supply not OK. | Check the compressed air supply and replace if necessary. |
Filter cartridges not inserted correctly. | Check filter cartridges for correct placement and insert correctly if necessary. Replacing filter cartridges | |
Rotary nozzles tilted or damaged. | Check the rotary nozzles and contact customer service if necessary. | |
End caps of the rotary nozzles loose or fallen off. | Check the top and bottom end caps of both rotary nozzles and contact customer service if necessary. | |
Service LED illuminates continuously. | Filter cartridges or filter membranes are defective/saturated. | Set the <On/Off> switch to <Off> to clean the filter membrane. The filter membranes are cleaned twice. Change filter cartridges. Replacing filter cartridges |
The power LED illuminates after initialization but the motors fail to start. | Control board defective. | Check and replace the control board as needed, or contact customer service. |
Power relay defective | Check and replace the power relay as needed, or contact customer service. |