Technical data

Table: General technical data

 

xFUME® FLEX FC

xFUME® FLEX

Mains voltage

115 V

230 V

Mains frequency

50 Hz/60 Hz

50 Hz

Drive capacity

1.1 kW

1.1 kW

Main filter area

22 m²

22 m²

Prefilter area

0.43 m²

0.43 m²

Filter class

H13

H13

Degree of separation

≥ 99 %

≥ 99 %

Length of extraction arm

2 m, 3 m or 4 m

2 m, 3 m or 4 m

Connection diameter extraction hose

170 mm

170 mm

Exhaust air opening

310 mm x 142 mm

310 mm x 142 mm

Max. volume flow

1200 m³/h

1200 m³/h

Sound pressure level LpA

≤72 dB(A)

≤72 dB(A)

Weight

129 kg

129 kg

Dimensions (LxWxH)

700 mm x 700 mm x 1095 mm

700 mm x 700 mm x 1095 mm

Table: Ambient conditions for transport and storage

Temperature of the ambient air

-20 °C to +55 °C

Table: Ambient conditions for operation

Temperature of the ambient air

-10 °C to +40 °C

Relative air humidity

Up to 50 % at +40 °C
Up to 90 % at +20 °C